Home Company and Product News News from WANNER INTERNATIONAL

News from WANNER INTERNATIONAL

Hydra-Cell® pulse-less MT8 metering pump has ATEX certification
The Hydra-Cell MT8 low-flow, high-pressure metering and dosing pump is now available with ATEX Zone 2 certification.

It conforms to ATEX Group ll, Category 3, Zone 2, gas group (IIC) and temperature class (T5 or T4 depending on process liquid temperature). This means the MT8 is classified for use in explosive atmospheres consisting of a mixture of air and flammable substance in the form of gas, vapour or mist that is not likely to occur in normal operation, but if it does occur will persist for a short time only
For Category 3, Zone 2, a protective system is not always required. In this case, an oil level sight bowl is fitted to the drive side of the Hydra-Cell pump to allow easy monitoring by the user.
As with all ATEX approved Hydra-Cell pumps, the MT8 features an ATEX nameplate fixed to the pump housing that displays the markings of conformity to prove the pump is “suitable for use” in the zones for which it is certified. The nameplate also indicates the specific ATEX Zone classification. Each pump is fitted with an earth stud to test for earth continuity.
To achieve its low flow accuracy, the MT8’s flow rate is controlled by altering the pump RPM by an ATEX precision variable gearbox. Keeping a constant diaphragm stroke length ensures a constant compression ratio and excellent accuracy in very large turndown applications. The variable gearbox has a lock option to stop unauthorised adjustments.


Wanner International
T: +44 (0)1252 816847
Email: brenda@wannerint.com
www.hydra-cell.co.uk